POWER FLUSHING is the process of individually cleaning the sludge, debris and blockages from your radiators and central heating pipework with chemicals at high pressure and temperature using a specialised Powerflush machine
Here are the stages in Power flush.
How to POWER FLUSH a CENTRAL HEATING SYSTEM :
Locate Powerflushing machine close to supply of mains water and close to foul water waste drain
Isolate mains water supply
Isolate cold feed
Fit temporary cap to expansion/vent pipe
Set thermostatic radiator valves to maximum
Remove thermostatic valve heads
Close by-pass
Close auto by-pass (if present)
Remove magnetic filter connect to pipework/isolation valves after removal of filter or connect to boiler tails
Circulate SENTINEL X800 JETFLO system cleaner throughout system
Turn on boiler, heat system to minimum 50°C
Reverse flow regularly
Isolate cylinder (if applicable)
Open radiator 1
Circulate system cleaner through radiator 1 only
Reverse flow regularly
Close radiator 1
Open radiator 2
Circulate system cleaner through radiator 2 only
Repeat this process with all the remaining radiators on the system
Dump radiators individually and in reverse order
Dump until water runs clear
Repeat steps on all radiators on the system
TEST FOR CONTAMINANTS:
Use a turbidity tube to ensure that no particulate or solid contaminants still present
Insert SENTINEL X100 corrosion and Central Heating inhibitor to protect system to prevent sludge and limescale buildup in central heating system. Compliant with: BS7593 and Building Regulations Part L
Repressurise boiler and system
Use an Infrared Camera to demonstrate
even heating of radiators with cold spots and sludge removed